- 09.10.2026 · 1.2
-
A plot can now have curved sides and rounded corners, and margins and road widening follow them.
- 3.3.12, 3.3.13: the junction rounding note no longer appears where the corner is already drawn round.
- 09.10.2026 · 1.1
-
These readings changed:
- The building Citiwise fits is now the fewest floors that use at least 98% of the potential. Taller options are still listed.
- A building stays below 500 m² a floor, and so out of 1.3(93)(xiv), whenever that already uses the potential.
- 7.8: IT buildings take their FSI in the industrial zone too.
- 6.4 and Table 6-H: industrial buildings in the industrial zone take their margins and FSI from Table 6-H.
- 13.6(B): a special building with a fire tower needs one lift plus the tower's lift, not a second lift and staircase.
- Table 12-A, 12-G and 12-K: water and sanitation for hospitals by beds and hotels by rooms.
- Table 7-A: the additional FSI for hotels, hospitals and IT is now in the premium total.
The report now draws the open space taken off the floor plate, says when a drawn plot differs from the area entered, and lists approvals and items to confirm on their own sheets.
- 08.10.2026 · 1.0
-
Public at citiwise.in: the site, a printable report, and a connector for Claude, ChatGPT and other apps.
These readings changed:
- Table 6-D: side and rear margins follow the road-width row (note 1), with H/5 once the row's own height is passed (6.2.3(b)). Where some authorities read by plot size, a note says so.
- Special buildings, 1.3(93)(xiv) and 3.3.9: 6 m on every side above 24 m, and for listed uses with a floor of 500 m² or more, with the 12 m road they need.
- 6.1.2(b): congested assembly buildings and mangal karyalayas take non-congested margins; other congested buildings switch above 24 m, not at it.
- 6.0 and Table 6-C: congested holdings over 0.4 ha take non-congested margins.
- 6.10.1(i): the height limit leaves out a parking floor up to 6 m.
- 6.10.1(ii): every use needs a 12 m road above 24 m.
- Table 6-E: colleges and mangal karyalayas take 3 m on all sides.
- 9.27.1: one lift above 15 m, two above 24 m.
- Table 8-B: no parking for bungalows up to 300 m² and row houses up to 100 m²; carpet bands without gaps.
- Table 9-G: houses above G+2 need 1.0 m stairs.
- 7.8.2, 7.8.3: IT FSI on 12, 18 and 27 m roads applies everywhere, not only in MMR and Pune.
Added: the area statement in the form of Proforma I (Appendix A), premiums and payment options (2.2.14), TDR loading and DRC (11.2.6, 11.2.7), refuge areas (9.29.6), fire lift and fire tower (9.29.8, 13.6), indicative fire tanks (9.32), open space and amenity space (3.4, 3.5), inclusive housing (3.8), sanitation (12.6), stair risers and treads (9.29.3), NOCs.