How Citiwise is checked
UDCPR 2020 as amended to 30.01.2025. Every test below last ran on 02.11.2026.
People buy and price land on these numbers, so here is exactly how we test them. The strongest tests replay whole cases an authority has worked out, figure by figure. Around them sit tests written from the clause text, and 5,602 values from 328 real scrutiny reports, sorted against the rules. Citiwise can still get things wrong, which is why every number has its clause next to it. Check the ones you are relying on.
Tests
| Test | Result |
|---|---|
| One real scrutiny report replayed from its plot, figure by figure: area statement, FSI, road widening, height, margins, water and sanitation | 20 / 20 |
| A whole sanctioned proposal replayed from its inputs: area statement, FSI, development rights, parking and water, figure by figure | 16 / 16 |
| Rule tests written from the clause text | 113 / 113 |
| Cases where this site and the connector agree | 1,676 / 1,676 |
| Plots with inward corners where this site and the connector agree | 24 / 24 |
The 5,602 values from 328 scrutiny reports are not pass or fail. Each is sorted into one of three groups, explained below.
| Scrutiny values | Values |
|---|---|
| Match a figure the regulation itself gives | 4,366 |
| Of the form the regulation gives, where the exact figure depends on details the reports do not keep | 1,231 |
| Not explained by any rule in Citiwise yet | 5 |
What each test does
Whole cases, replayed
Two tests put a real case into Citiwise and compare every figure that comes out with the figure the authority printed. The first is a Municipal Council's scrutiny report for a plot in a congested area: its plot area, road, road widening, height and flats go in, and 20 figures come back to be compared, from the balance plot and the FSI to the margins on each side, the overhead tank and the number of water closets. The second is a sanctioned proposal, replayed from the inputs on its drawing, with 16 figures compared in the same way. A figure passes when it agrees to the second decimal place.
Scrutiny values, one by one
When a proposal is submitted for building permission under UDCPR, the scrutiny checks each figure on the drawings against the regulations, and for every check the proposal fails it prints the value the regulations permit. Citiwise holds 328 such reports with 5,602 printed values. A report keeps the item checked and the permitted value, but not the drawing behind it, so these cases cannot be replayed from their inputs. Each value is sorted instead into one of three groups.
- Matches the regulation
- The value is one the regulation gives on its own, from its table or its text, such as a stair width in Table 9-G or a floor height in Table 9-A. It shows that the rule Citiwise holds produces that figure. It does not show that Citiwise would have reached it for that plot, because the plot is not known.
- Of the regulation's form
- The value is the kind of figure the rule produces, such as a whole number of water closets, a side margin within the 12 m cap of 6.2.3 or a refuge area above its minimum, but the exact figure depends on room or plot details the report does not keep. These values contradict nothing in Citiwise, and they prove nothing either.
- Not explained
- No rule Citiwise holds gives the value. It points to a rule Citiwise does not have yet, or to a slip in the scrutiny itself.
So the values that match are figures the rules give, not plots reproduced. The whole cases above are the test of whole plots.
| Item checked, and the clause it is checked against | Values | Match | Of its form | Not explained |
|---|---|---|---|---|
| Stair width and tread Table 9-G; 9.29.3(iv) | 1,914 | 1,914 | 0 | 0 |
| Kitchen ventilation and bath sizes 9.20.1; 9.4.1 | 1,183 | 750 | 433 | 0 |
| Risers 9.29.3(v) | 1,068 | 1,068 | 0 | 0 |
| Water closets 12.6; Tables 12-C to 12-P | 337 | 0 | 337 | 0 |
| Side and rear margins Tables 6-B to 6-E; 6.2.3 | 272 | 151 | 121 | 0 |
| Overhead water tank 12.5; Table 12-A | 206 | 203 | 2 | 1 |
| Urinals 12.6; Tables 12-C to 12-P | 155 | 0 | 155 | 0 |
| Bathrooms 12.6; Tables 12-C to 12-P | 127 | 0 | 127 | 0 |
| Underground water tank 12.5 | 97 | 86 | 11 | 0 |
| Lifts 9.27.1 | 96 | 96 | 0 | 0 |
| Floor heights Table 9-A | 77 | 77 | 0 | 0 |
| Refuge area 9.29.6 | 43 | 6 | 37 | 0 |
| Amenity space 3.5.1; 5.1.8 | 10 | 0 | 7 | 3 |
| Mezzanine headroom 9.7.2 | 7 | 7 | 0 | 0 |
| Internal chowk 6.9 | 7 | 7 | 0 | 0 |
| Front margin Tables 6-B to 6-E | 2 | 1 | 0 | 1 |
| Playground 3.4.1(vii) | 1 | 0 | 1 | 0 |
Rules and agreement
The 113 rule tests are written from the words of the clauses, one or more for each reading Citiwise makes, such as which margins a congested assembly building takes, where the height limit leaves out a parking floor, or when a building needs a lift. The site also runs its own copy of the rules in the browser, and 1,676 cases are worked by both and compared figure by figure: built-up, floors, height, floor plate, margins, lifts and parking. Plots with inward corners are compared on their own.
Each of the 701 regulations and tables of UDCPR, across its 15 chapters, is accounted for. 527 are worked into the study's figures, conditions and schedules, and 67 more are set out on the pages. 102 are definitions, procedure, the powers of an authority or the inner workings of a scheme, each recorded with what it is. 5 have ceased to operate under UDCPR itself.
Each of the 155 tables of the rules data is accounted for. 32 are read for the figures, and 6 more are checked against the text of UDCPR or against the figures Citiwise works out. 3 have been replaced by UDCPR itself or by a later table. The rest are names and settings, or records of proposals and people, which are never copied.
Every test runs before a change to a rule is published, and the date at the top of this page is the last time they ran.
Scope
The tests check Citiwise against UDCPR 2020 as amended to 30.01.2025, the text on the UDCPR pages, each of which links to the official consolidated text. The reports and the proposal come from cases scrutinised under UDCPR, and they do not cover every authority or every kind of building. A figure for a case they never met is checked only by the rule tests and by the clause printed beside it, which is why every figure carries one.
What stays private
The scrutiny reports and the sanctioned proposal belong to the people who submitted them. They stay on one machine, and only the counts on this page leave it. No name, place, plot or drawing from them is published.
How a number is made
- Every rule value comes from UDCPR's own tables and text. Where a figure is indicative, like fire tanks, the report says so.
- Where UDCPR leaves room for reading it two ways, Citiwise follows the text and tells you.
- The site and the connector run the same rules, and we test one against the other on every change.
- Whenever a rule changes, it goes in the changelog with its clause.
Covered
Citiwise covers every authority that follows UDCPR, on a plot of any shape. It gives you the area statement in the Proforma I format, FSI, premium and TDR by road width, road widening and in-situ TDR, height, and margins on every side for congested and non-congested areas, including plots with more than one road, a nallah, a river or a railway, and the common wall of a semi-detached house or of row houses, which keeps no margin (Table 6-D note 4 and Sr. 6). It also covers special buildings, minimum plot sizes, parking, water, sanitation, stairs, lifts, refuge areas, fire tanks (indicative), open space, amenity space, inclusive housing, and the NOCs your height, use or location triggers.
Not covered
Greater Mumbai and the other areas regulation 1.1(i) leaves out, which are MIDC areas, NAINA, the Jawaharlal Nehru Port Trust area, the hill-station municipal councils, the Chikhaldara notified area, notified eco-sensitive regions and Lonavala, follow rules of their own, and Citiwise does not assess plots there.
If you find something wrong, email us the plot details and the clause. We will fix it and note it in the changelog.