UDCPR 2020 / Chapter 3, General land development requirements
3.3.2 Roads / streets in Land Sub-division or Layout
UDCPR 2020 as amended to 30.01.2025
A) For Residential Development - The minimum width of internal road in any layout or subdivision of land shall be as given in Table No.3A. Table No.3A - Internal Roads for Residential Development
Sr. Length of Internal Road in Width of Internal Road in Layout /
No. Layout / Sub division (m.) Sub Division (m.)
i Upto 150 9.00
ii Above 150 and upto 300 12.00
iii Above 300 15.00
Note - For layout or part of layout where plots of 100 Sq.m. or less are proposed for Economical weaker Sections (EWS), 4.5 m. wide road of length upto 60.0 m. and 6.0 m. wide road of length upto 100 m. may be permitted so that EWS plots shall abut on both sides of such roads.
B) For Other than Residential Development : The minimum width of internal road in any layout or subdivision of land shall be as given in Table No.3B. Table No.3B - Internal Roads for non-residential Development
Sr. Length of Internal Road in Width of Internal Road in Layout / Sub
No. Layout / Sub division (m.) Division (m.)
i Upto 150 12.0
ii Above 150 and upto 300 15.0
iii Above 300 18.0 or more
C) Group Housing Scheme : In case of group housing schemes, minimum width of internal roads shall be as given in Table No.3C. Table No.3C - Internal Roads for Group Housing Scheme
Sr. No. Length of Internal Road (m.) Width of Internal Road (m.)
i Upto 150 7.50
ii Above 150 and upto 300 9.00
iii Above 300 and upto 600 12.00
iv Above 600 15.00
Note : It shall be necessary to provide through roads in group housing scheme of area more than 2.0 Hectares, so as to coordinate the adjoining major road links (15.0 m. and above) or give way to new road link for adjoining area. The width required for such road link shall be as per Table No.3A. This shall not bar coordination of smaller width roads approaching from adjoining area, if owners so desire. Further the Authority may insist on coordination of smaller width roads from adjoining area, if required from planning point of view.
D) Pathways In case of Group Housing Scheme / Campus planning / Layout of Buildings, a pedestrian approach to the buildings from road / street / internal means of access, wherever necessary, shall be through paved pathway of width not less than 2.0 m., 3.0 m. & 4.5 m. provided its length measured from exit way of the building is not more than 40 m., 60 m. and 100 m. respectively from the main / internal means of access. If the length is more than 100 m., then width of the road as provided in Table No.3C shall be necessary. The marginal distances shall not be required from such pathways. However, distance between two buildings shall be maintained which will include width of such pathway.
To see how 3.3.2 and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.
The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.