UDCPR 2020 / Chapter 6, General building requirements - setback, marginal distance, height and permissible FSI

6.8 Exclusion of structures / projections for FSI calculation

UDCPR 2020 as amended to 30.01.2025

i) Exclusion of Structures / Projections for FSI Calculation Structures / Projections / features / ornamental projection of glass façade permitted in marginal open spaces as mentioned in Regulation No.6.7 (a), (c), (d), (e), (f)(iii), (g), (1)(--), (j), (k).

ii) Stilt / Multi-storeyed floors / podium / basement, if used (2) exclusively for parking including passages (2) and staircase, Lift Duct / Lobby therein and basement used for users mentioned in Regulation No.9.11.1(i) to (iii).

iii) Areas covered by Porches, Canopies, lofts, ledge or tand, shelves, Air Conditioning Plant Rooms, Lift Well, Lift-Machine Room and Service Floor of height not exceeding 1.8 m. height (2) or as permissible as per Regulation No.9.33 below the beam, for hospitals, shopping malls, plazas and Star category hotels (rating with three stars and above) and like buildings, other buildings above 15.0 m. in height.

iv) Area of structures for water, grey water, wet-waste or an effluent treatment plant, rain water harvesting Pump rooms, (1) (--) electric cabin of sub-stations / of generator set area, electric meter rooms as per requirements, Refuge chutes / garbage chutes /garbage shafts for wet and dry garbage separately with collection chambers.

v) Rockery, Well and well structures, Plant Nursery, Water Pool, platform around a tree, Fountain, bench, Chabutara with open top and unenclosed sides, Ramps, Compound wall, Gate, slide / swing, Steps outside the buildings, Domestic working place (open to sky), Overhead water tank on top of the building, Refuge area for high rise buildings as specified in Regulation No.9.29.6

vi) Telecommunication tower, antenna and allied activities.

vii) Atrium may be allowed in any type of building. Such atrium may be allowed to be enclosed on top by transparent or opaque sheet.

viii) Open to sky terraces, top of podium, open to sky swimming pool on the top terrace and top of podium with plant room.

ix) Structures permissible in recreational open space as per Regulation No.3.4.7.

(1) The words (i) & „maximum 10 Sq.m.‟ deleted vide Corrigendum / Addendum CR.121/21, dt.02nd December, 2021

(2) Inserted vide Corrigendum / Addendum CR.121/21, dt.02nd December, 2021

To see how 6.8 and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.

The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.