UDCPR 2020 / Chapter 9, Requirements of part of building

9.29.8 Fire lift

UDCPR 2020 as amended to 30.01.2025

Where applicable, fire lifts shall be provided with a minimum capacity for 8 passengers and fully automated with emergency switch on ground level. In general, buildings 15.0 m. in height or above shall be provided with fire lifts. In case of fire, only fireman shall operate the fire lift. In normal course, it may be used by other persons. Each fire lift shall be equipped with suitable inter-communication equipment for communicating with the control room on the ground floor of the building. The number and location of fire lifts in a building shall be decided after taking into consideration various factors like building population, floor area, compartmentation, etc.

To see how 9.29.8 and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.