UDCPR 2020 / Chapter 9, Requirements of part of building
9.30 Architectural projections
UDCPR 2020 as amended to 30.01.2025
Architectural Projections may be allowed to the following extent. Horizontal Vertical (above building) H/20, subject to min 0.3 m. and max 3.0 m. exclusive of H / 20, subject to max. 6.0 m. side and rear marginal distance of 6.0 m. required for movement for fire fighting vehicle in case of special buildings. Where H = Height of building from ground level. The owner shall submit the undertaking to the authority that, such architectural projection shall not be converted to any habitable or other purpose.
To see how 9.30 and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.
The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.