UDCPR 2020 / Chapter 9, Requirements of part of building
9.5.1 Location and extent
UDCPR 2020 as amended to 30.01.2025
Ledge or Tand may be provided at suitable places as per requirement. Lofts may be provided over kitchen, habitable rooms, bathrooms, water closets, and corridor within a tenement in residential buildings, over shops and in industrial building, as mentioned in below Table No.9-B subject to the following restrictions –
i) The clear head room under the Loft shall not be less than 2.1 m.
ii) Loft in commercial areas and industrial building shall be located 2.0 m. away from the entrance.
iii) Loft shall not interfere with the ventilation of the room under any circumstances.
iv) The maximum height of loft shall be 1.5 m. Table No.9-B - Provision of Loft Sr. Maximum Coverage Rooms over which Permitted No. (Percentage to area or room below)
(1) (2) (3)
1 Kitchen / Habitable room 25
2 Bathroom, water closet, corridor 100
3 Shops with width up to 3.0 m. 33
4 Shops with width exceeding 3.0 m. 50
5 Industrial 33To see how 9.5.1 and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.
The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.