UDCPR 2020 / Chapter 9, Requirements of part of building
Table 9-G Minimum width of staircase
UDCPR 2020 as amended to 30.01.2025
Table No.9-G - Minimum width of staircase
Minimum width of
S. No Use of Building
Stair Case (in m.)
1 Residential Buildings
a) Individual Housing upto G + 2 storeys 0.75
b) Multi-storied Residential Building upto 15 m. height 1.00
c) Multi-storied Residential Building above 15 m. &
1.20
upto 24 m. height
(#) d) Multi-storied Residential Building above 24 m.height 1.50
2 Residential hotel buildings 1.50
3 Assembly Building likes auditorium, theatres, cinemas, 2.00
multiplex, mangal karyalaya, marriage halls, etc.
4 Institutional &Educational Buildings. 2.00
5 All other buildings excluding Sr.No. (1) to (4) above 1.50
(1)
Note - Internal staircase for duplex tenements shall be of minimum width 0.75 m. and for
mezzanine floor shall be of minimum width 0.90 m.