UDCPR 2020 / Chapter 9, Requirements of part of building
9.2.2 Height of Habitable Rooms
UDCPR 2020 as amended to 30.01.2025
The minimum and maximum height of a habitable room shall be given in Table No.9-A hereunder :
Sr. Occupancy Minimum Height Maximum Height
No. (m.) (m.)
(1) (2) (3) (4)
1 Flat Roof -
a) Any habitable room 2.75 4.5
a1) Habitable room in EWS / LIG Housing. 2.75 4.2
b) Air-conditioned habitable room 2.4 4.5
c) Assembly Halls, Residential Hotels of 3 3.0 6.00 or higher
star category and above, Institutional, (2.40 m. in case according to the
Educational, Industrial, Hazardous or storage of Air requirement of
occupancies, Departmental Stores, Malls, IT conditioned occupancy.
Buildings, Office Buildings, Exhibition room)
Centre, Convention Hall, Theatre, Film Studio, Entrance Halls and Lobbies to these buildings.
d) Shops 3.00 4.5
2 Pitched roof-
a) Any habitable room 2.75 (average 4.5 (average with
with 2.0 m. at the 3.2 m. at the lowest lowest point) point)
b) Habitable room in EWS / LIG Housing. 2.6 (average with 4.2 (average with 2.0 m. at the 3.2 m. at the lowest lowest point) point)
Provided that the minimum head-way under any beam shall be 2.4 m.
Provided further that height more than that specified above, if required for particular occupancy, shall not be counted towards calculation of FSI.