UDCPR 2020 / Chapter 9, Requirements of part of building
9.28.8 Width of staircase
UDCPR 2020 as amended to 30.01.2025
The minimum width of staircases / corridors for various buildings shall be as below. Table No.9-G - Minimum width of staircase Minimum width of
S. No Use of Building Stair Case (in m.) 1 Residential Buildings
a) Individual Housing upto G + 2 storeys 0.75
b) Multi-storied Residential Building upto 15 m. height 1.00
c) Multi-storied Residential Building above 15 m. & 1.20 upto 24 m. height
(#) d) Multi-storied Residential Building above 24 m.height 1.50
2 Residential hotel buildings 1.50
3 Assembly Building likes auditorium, theatres, cinemas, 2.00
multiplex, mangal karyalaya, marriage halls, etc.
4 Institutional &Educational Buildings. 2.00
5 All other buildings excluding Sr.No. (1) to (4) above 1.50
(1)
Note - Internal staircase for duplex tenements shall be of minimum width 0.75 m. and for mezzanine floor shall be of minimum width 0.90 m.
To see how 9.28.8 and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.
UDCPR 2020, 9.28.8, as amended to 30.01.2025. https://citiwise.in/udcpr/9-28-8
Source
These words are UDCPR 2020 as the Directorate of Town Planning, Government of Maharashtra, publishes it in its consolidated text, as amended to 30.01.2025 with earlier provisions and corrections. 9.28.8 is printed on page 165 of that text. Read the official text (PDF).