UDCPR 2020 / Chapter 9, Requirements of part of building

9.28.8 Width of staircase

UDCPR 2020 as amended to 30.01.2025

The minimum width of staircases / corridors for various buildings shall be as below. Table No.9-G - Minimum width of staircase Minimum width of

S. No Use of Building Stair Case (in m.) 1 Residential Buildings

a) Individual Housing upto G + 2 storeys 0.75

b) Multi-storied Residential Building upto 15 m. height 1.00

c) Multi-storied Residential Building above 15 m. & 1.20 upto 24 m. height

         (#)        d) Multi-storied Residential Building above 24 m.height                  1.50
          2         Residential hotel buildings                                              1.50
          3         Assembly Building likes auditorium, theatres, cinemas,                   2.00

multiplex, mangal karyalaya, marriage halls, etc.

          4         Institutional &Educational Buildings.                                    2.00
          5         All other buildings excluding Sr.No. (1) to (4) above                    1.50

(1)

Note - Internal staircase for duplex tenements shall be of minimum width 0.75 m. and for mezzanine floor shall be of minimum width 0.90 m.

To see how 9.28.8 and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.

The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.