UDCPR 2020 / Chapter 12, Structural safety, water supply, drainage and sanitary requirements, outdoor display and other services
Table 12-D Sanitation Requirements – Factories
UDCPR 2020 as amended to 30.01.2025
Table No.12-D : Sanitation Requirements – Factories
Sr. Fixtures Offices / Visitors Workers
No. Male Female Male Female
(1) (2) (3) (4) (5) (6)
i) Water Closets 1 for up to 25 1 for up to 15 1 for up to 1 for up to 12
(Workers & Staff) 2 for 16-35 2 for 16-25 15 2 for 13-25
3 for 36-65 3 for 26-40 2 for 16-35 3 for 26-40
4 for 66-100 4 for 41-57 3 for 36-65 4 for 41-57
5 for 58-77 4 for 66-100 5 for 58-77
6 for 78-100 6 for 78-100
For persons 101 - 200 add 3% 5% 3% 5%
For persons over 200 add 2.5 % 4% 2.5 % 4%
ii) Urinals Nil up to 6 - Nil up to 6 -
1 for 7-20 1 for 7-20
2 for 21-45 2 for 21-45
3 for 46-70 3 for 46-70
4 for 71-100 4 for 71-100
For persons 101 - 200 add 3% 3%
For persons over 200 add 2.5 % 2.5 %