UDCPR 2020 / Chapter 12, Structural safety, water supply, drainage and sanitary requirements, outdoor display and other services
Table 12-C Sanitation Requirements - Office Buildings
UDCPR 2020 as amended to 30.01.2025
Table No.12-C : Sanitation Requirements - Office Buildings
Sr. Fixtures Public Toilets Staff Toilets
No. Male Female Male Female
(1) (2) (3) (4) (5) (6)
i) Executive Rooms and Conference Unit could be common For individual officer
Halls in Office Buildings for Male / Female or rooms
Toilet suite comprising one WC, separate depending on
one washbasin (with optional the number of user of
shower stall if building is used each facility
round the clock at user‘s option)
Pantry optional as per user
requirement
ii) Main Office Toilets for Staff and
Visitors
a) Water-closet 1 per 25 1 per 15 1 per 25 1 per 15
b) Urinals Nil up to 6 - Nil up to 6 -
1 for 7-20 1 for 7-20
2 for 21-45 2 for 21-45
3 for 46-70 3 for 46-70
4 for 4 for
71-100 71-100
Add @ 3% for 101-200 101-200
Add @ 2.5 % Over 200 Over 200