UDCPR 2020 / Chapter 12, Structural safety, water supply, drainage and sanitary requirements, outdoor display and other services

Table 12-F Sanitation Requirements - Art Galleries, Libraries and Museums

UDCPR 2020 as amended to 30.01.2025

Table No.12-F- Sanitation Requirements - Art Galleries, Libraries and Museums
Sr.      Fixtures                                  Public                                    Staff
No.                                  Male                      Female              Male              Female
(1)        (2)                       (3)                         (4)                (5)               (6)
 i)   Water-closets       1 per 200 up to 400          1 per 100 up to 200     1 for up to 15 1 for up to 12
                          Over 400 add at 1 per Over 200 add at 1 per 2 for 16-35               2 for 13-25
                          250 or part thereof   150 or part thereof
ii)   Urinals             1 per 50                     -                       Nil up to 6      -
                                                                               1 per 7-20
                                                                               2 per 21-45
Notes - Male population may be assumed as two-third and female population as one-third.

          Table No.12-G Sanitation Requirements - Hospitals with Indoor Patient Wards
Sr.          Fixtures                            Patient Toilets                            Staff Toilets
No.                                       Male                 Female                Male                Female
(1)               (2)                      (3)                     (4)                (5)                   (6)
 i)    Toilet         suite         Private room with up to 4 patients          For individual          doctor‘s     /
       comprising one WC                                                        officer‘s rooms
       and one washbasin
       and shower stall
For General Wards, Hospital Staff and Visitors
ii)    Water-closets                1 per 8 beds or      1 per 8 beds or        1 for up to 15      1 for up to 12
                                    part thereof         part thereof           2 for 16-35         2 for 13-25
iii)   Urinals                      1 per 30 beds        -                      Nil up to 6         -
                                                                                1 for 7 to 20
                                                                  2 for 21-45
Note - Male population may be assumed as two-third and female population as one-third.

         Table No.12-H Sanitation Requirements - Hospitals - Outdoor Patient Department
Sr.            Fixtures                     Patient Toilets                     Staff Toilets
No.
                                                 Male               Female            Male                  Female
(1)                     (2)                       (3)                 (4)              (5)                    (6)
 i)    Toilet suite comprising one         For up to 4 patients                  For individual          doctor‘s        /
       WC and one washbasin                                                      officer‘s rooms
       (with optional shower stall
       if building used for 24 h)
ii)    Water-closets                       1per       100     2 per 100          1 for up to 15         1 for up to
                                           persons      or    persons or part    2 for 16-35            12
                                           part thereof       thereof                                   2 for 13-25
ii)    Urinals                             1     per    50    -                  Nil up to 6            -
                                           persons      or                       1 per 7 to 20
                                           part thereof                          2 per 21-45
Note - Male population may be assumed as two-third and female population as one-third.

                 Table No.12-I Sanitation Requirements - Hospitals’ Administrative Buildings
Sr.                    Fixtures                                        Staff Toilets
No.
                                                                   Male                          Female
(1)                           (2)                                   (3)                            (4)
i)     Toilet suite comprising one WC and             For individual doctor‘s / officer‘s rooms
       one washbasin (with optional shower
       stall if building used for 24 h)
ii)    Water-closets                       1 per 25 persons or part                1 per 15 persons or part
                                           thereof                                 thereof
iv) Urinals                                Nil up to 6                             -
                                           1 per 7 to 20
                                           2 per 21-45
Note - Some WC‘s may be European style if desired.

       Table No.12-J Sanitation Requirements - Hospitals’ Staff Quarters and Nurses Homes
Sr.        Fixtures                       Staff Quarters                            Nurses Homes
No.                                  Male                Female                Male            Female
(1)          (2)                      (3)                  (4)                  (5)              (6)
 i)     Water-closets        1 per 4 persons or        1per 4 persons     1 per 4 persons   1per 4 persons
                             part thereof              or part thereof    or part thereof   or part thereof
                                                                          2 for 16-35       2 for 16-35

                                Table No.12-K Sanitation Requirements - Hotels
Sr.          Fixtures                          Public Rooms                         Non-Residential Staff
No.                                     Male                   Female               Male          Female
(1)               (2)                    (3)                     (4)                 (5)             (6)
 i)   Toilet        suite Individual guest rooms with attached                  -
      comprising     one toilets
      WC,      washbasin
      with shower or a
      bath tub
Guest Rooms with Common Facilities
 ii)  Water-closets       1 per 100 persons 2 per 100 persons                   1 for up to 15      1 for up to
                          up to 400           up to 200                         2 for 16-35         12
                          Over 400 add at 1 Over 200 add at 1                   3 for 36-65         2 for 13-25
                          per 250 or part per 100 or part                       4 for 66-100        3 for 26-40
                          thereof             thereof                                               4 for 41-57
                                                                                                    5 for 58-77
                                                                                                    6 for 78-100
iii)    Urinals                  1 per 50 persons or
                                                 Nil, upto 6 persons Nil up to 6                    -
                                 part thereof    1 for 7-20 persons    1 for 7 to 20
                                                 2 for 21-45 persons 2 for 21-45
                                                 3 for 46-70 persons 3 for 46-70
                                                 4     for    71-100 4 for 71-100
                                                 persons
Note - Male population may be assumed as two-third and female population as one-third.

                             Table No.12-L Sanitation Requirements – Restaurants
Sr.     Fixtures                        Public Rooms                             Non-Residential Staff
No.                              Male                     Female                 Male            Female
(1)        (2)                    (3)                       (4)                   (5)              (6)
 i)     Water           1 per 50 seats up to 200   2 per 50 seats up to    1 for up to 15        1 for up to 12
        Closets         Over 200 add at 1 per      200                     2 for 16-35           2 for 13-25
                        100 or part thereof        Over 200 add at 1       3 for 36-65           3 for 26-40
                                                   per 100 or part         4 for 66-100          4 for 41-57
                                                   thereof                                       5 for 58-77
                                                                                                 6 for 78-100
 ii)    Urinals         1 per 50 persons or part   ----          Nil up to 6                     ----
                        thereof                                  1 for 7-20
                                                                 2 for 21-45
                                                                 3 for 46-70
                                                                 4 for 71-100
NOTE : Male population may be assumed as two-third and female population as one-third.

            Table No.12-M Sanitation Requirements – Schools and Educational Institutions
Sr.      Fixtures             Nursery                 Non-Residential                              Residential
No.                           School
                                                   Boys                Girls                Boys                 Girls
(1)        (2)                  (3)                  (4)                (5)                  (6)                  (7)
i)     Water           1 per 15 pupils 1 for 40 pupils 1 per 25 pupils 1 per 8 pupils 1 per 6 pupils
       Closets         or part thereof or part thereof or part thereof or part thereof or part thereof

ii)    Urinals         ----                    1 per 20 pupils ----                    1 per 25 pupils ----
                                               or part thereof                         or part thereof

                                Table No.12-N Sanitation Requirements – Hostels
Sr.    Fixtures               Resident                           Non-Resident                Visitor / Common Rooms
No.                   Male            Female               Male               Female               Male           Female
(1)       (2)          (3)               (4)               (5)                 (6)                 (7)              (8)
i)     Water        1 per 8 or 1 per 6 or 1 for up to 15               1 for up to 12      1 per 100 up 1 per 200 up
       Closet       part       part       2 for 16-35                  2 for 13-25         to 400       to 200
                    thereof    thereof                                                     Over 400 add Over    200
                                          3 for 36-65                  3 for 26-40
                                                                                           at 1 per 250 add at 1 per
                                                    4 for 66-100       4 for 41-57
                                                                       5 for 58-77
                                                                       6 for 78-100
iii)   Urinals      1 per 25 ----                   Nil up to 6        ----                1 per 50 or ----
                    or    part                      1 for 7-20                             part thereof
                    thereof
                                                    2 for 21-45
                                                    3 for 46-70
                                                    4 for 71-100

  Table No.12-O Sanitation Requirements – Mercantile Buildings, Commercial Complexes, Shopping
                                Malls, Fruit & Vegetable Markets
Sr. Fixtures         Shop Owners          Common Toilets in Market /     Public Toilet for Floating
No.                                                Mall Building                 Population
                  Male        Female          Male            Female        Male          Female
(1)     (2)         (3)          (4)           (5)               (6)         (7)            (8)
 i)    Water        1 per 8 persons or part 1 for up to 15               1 for up to 12      1 per 50 1 per 50
       Closets      thereof                 2 for 16-35                  2 for 13-25         (Minimum (Minimum 2)
                                            3 for 36-65                  3 for 26-40         2)
                                            4 for 66-100                 4 for 41-57
                                                                         5 for 58-77
                                                                         6 for 78-100
iii)   Urinals          ----              ----       Nil up to 6               ----          1 per 50               ----
                                                     1 for 7-20
                                                     2 for 21-45
                                                     3 for 46-70
                                                     4 for 71-100

                Table No.12-P Sanitation Requirements – Airports and Railway Stations
Sr.    Fixtures       Junction Stations,       Terminal Railway and      Domestic and International
No.               Intermediate Stations and        Bus Stations                    Airports
                         Bus Stations
                      Male         Female       Male         Female         Male           Female
(1)       (2)          (3)           (4)         (5)           (6)           (7)             (8)
i)     Water-     3 for up to    4 for up to    4 for up to    5 for up to     Minimum - 2     Minimum - 2
       closet     1000 Add 1     1000 Add 1     1000 Add 1     1000 Add 1      for 200 - 2     For 200 - 2
                  per            per            per            per             For 400 - 9     For 400 - 9
                  additional     additional     additional     additional      For 600 - 12    For 600 - 12
                  1000 or part   1000 or part   1000      or   1000       or   For 800 - 16    For 800 - 16
                  thereof        thereof        part thereof   part thereof    For 1000 - 18   For 1000 - 18
ii)    Urinals    4 for up to    ----           6 for up to    ----            1 per 40 or     ----
                  1000. Add 1                   1000. Add                      part thereof
                  per                           1        per
                  additional                    additional
                  1000                          1000
iii)   Toilet     1 per 4000     1 per 4000     1 per 4000     1 per 4000      1 per 4000 1 per 4000
       for                                                                     (Minimum 1) (Minimum 1)
       Disabled

To see how Table 12-F and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.

The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.