UDCPR 2020 / Chapter 12, Structural safety, water supply, drainage and sanitary requirements, outdoor display and other services
Table 12-G Sanitation Requirements - Hospitals with Indoor Patient Wards
UDCPR 2020 as amended to 30.01.2025
Table No.12-G Sanitation Requirements - Hospitals with Indoor Patient Wards
Sr. Fixtures Patient Toilets Staff Toilets
No. Male Female Male Female
(1) (2) (3) (4) (5) (6)
i) Toilet suite Private room with up to 4 patients For individual doctor‘s /
comprising one WC officer‘s rooms
and one washbasin
and shower stall
For General Wards, Hospital Staff and Visitors
ii) Water-closets 1 per 8 beds or 1 per 8 beds or 1 for up to 15 1 for up to 12
part thereof part thereof 2 for 16-35 2 for 13-25
iii) Urinals 1 per 30 beds - Nil up to 6 -
1 for 7 to 20
2 for 21-45
Note - Male population may be assumed as two-third and female population as one-third.