Table No.12-H Sanitation Requirements - Hospitals - Outdoor Patient Department
Sr. Fixtures Patient Toilets Staff Toilets
No.
Male Female Male Female
(1) (2) (3) (4) (5) (6)
i) Toilet suite comprising one For up to 4 patients For individual doctor‘s /
WC and one washbasin officer‘s rooms
(with optional shower stall
if building used for 24 h)
ii) Water-closets 1per 100 2 per 100 1 for up to 15 1 for up to
persons or persons or part 2 for 16-35 12
part thereof thereof 2 for 13-25
ii) Urinals 1 per 50 - Nil up to 6 -
persons or 1 per 7 to 20
part thereof 2 per 21-45
Note - Male population may be assumed as two-third and female population as one-third.