UDCPR 2020 / Chapter 12, Structural safety, water supply, drainage and sanitary requirements, outdoor display and other services

Table 12-I Sanitation Requirements - Hospitals’ Administrative Buildings

UDCPR 2020 as amended to 30.01.2025

Table No.12-I Sanitation Requirements - Hospitals’ Administrative Buildings
Sr.                    Fixtures                                        Staff Toilets
No.
                                                                   Male                          Female
(1)                           (2)                                   (3)                            (4)
i)     Toilet suite comprising one WC and             For individual doctor‘s / officer‘s rooms
       one washbasin (with optional shower
       stall if building used for 24 h)
ii)    Water-closets                       1 per 25 persons or part                1 per 15 persons or part
                                           thereof                                 thereof
iv) Urinals                                Nil up to 6                             -
                                           1 per 7 to 20
                                           2 per 21-45
Note - Some WC‘s may be European style if desired.