UDCPR 2020 / Chapter 12, Structural safety, water supply, drainage and sanitary requirements, outdoor display and other services
Table 12-J Sanitation Requirements - Hospitals’ Staff Quarters and Nurses Homes
UDCPR 2020 as amended to 30.01.2025
Table No.12-J Sanitation Requirements - Hospitals’ Staff Quarters and Nurses Homes
Sr. Fixtures Staff Quarters Nurses Homes
No. Male Female Male Female
(1) (2) (3) (4) (5) (6)
i) Water-closets 1 per 4 persons or 1per 4 persons 1 per 4 persons 1per 4 persons
part thereof or part thereof or part thereof or part thereof
2 for 16-35 2 for 16-35
Table No.12-K Sanitation Requirements - Hotels
Sr. Fixtures Public Rooms Non-Residential Staff
No. Male Female Male Female
(1) (2) (3) (4) (5) (6)
i) Toilet suite Individual guest rooms with attached -
comprising one toilets
WC, washbasin
with shower or a
bath tub
Guest Rooms with Common Facilities
ii) Water-closets 1 per 100 persons 2 per 100 persons 1 for up to 15 1 for up to
up to 400 up to 200 2 for 16-35 12
Over 400 add at 1 Over 200 add at 1 3 for 36-65 2 for 13-25
per 250 or part per 100 or part 4 for 66-100 3 for 26-40
thereof thereof 4 for 41-57
5 for 58-77
6 for 78-100
iii) Urinals 1 per 50 persons or
Nil, upto 6 persons Nil up to 6 -
part thereof 1 for 7-20 persons 1 for 7 to 20
2 for 21-45 persons 2 for 21-45
3 for 46-70 persons 3 for 46-70
4 for 71-100 4 for 71-100
persons
Note - Male population may be assumed as two-third and female population as one-third.
Table No.12-L Sanitation Requirements – Restaurants
Sr. Fixtures Public Rooms Non-Residential Staff
No. Male Female Male Female
(1) (2) (3) (4) (5) (6)
i) Water 1 per 50 seats up to 200 2 per 50 seats up to 1 for up to 15 1 for up to 12
Closets Over 200 add at 1 per 200 2 for 16-35 2 for 13-25
100 or part thereof Over 200 add at 1 3 for 36-65 3 for 26-40
per 100 or part 4 for 66-100 4 for 41-57
thereof 5 for 58-77
6 for 78-100
ii) Urinals 1 per 50 persons or part ---- Nil up to 6 ----
thereof 1 for 7-20
2 for 21-45
3 for 46-70
4 for 71-100
NOTE : Male population may be assumed as two-third and female population as one-third.
Table No.12-M Sanitation Requirements – Schools and Educational Institutions
Sr. Fixtures Nursery Non-Residential Residential
No. School
Boys Girls Boys Girls
(1) (2) (3) (4) (5) (6) (7)
i) Water 1 per 15 pupils 1 for 40 pupils 1 per 25 pupils 1 per 8 pupils 1 per 6 pupils
Closets or part thereof or part thereof or part thereof or part thereof or part thereof
ii) Urinals ---- 1 per 20 pupils ---- 1 per 25 pupils ----
or part thereof or part thereof
Table No.12-N Sanitation Requirements – Hostels
Sr. Fixtures Resident Non-Resident Visitor / Common Rooms
No. Male Female Male Female Male Female
(1) (2) (3) (4) (5) (6) (7) (8)
i) Water 1 per 8 or 1 per 6 or 1 for up to 15 1 for up to 12 1 per 100 up 1 per 200 up
Closet part part 2 for 16-35 2 for 13-25 to 400 to 200
thereof thereof Over 400 add Over 200
3 for 36-65 3 for 26-40
at 1 per 250 add at 1 per
4 for 66-100 4 for 41-57
5 for 58-77
6 for 78-100
iii) Urinals 1 per 25 ---- Nil up to 6 ---- 1 per 50 or ----
or part 1 for 7-20 part thereof
thereof
2 for 21-45
3 for 46-70
4 for 71-100
Table No.12-O Sanitation Requirements – Mercantile Buildings, Commercial Complexes, Shopping
Malls, Fruit & Vegetable Markets
Sr. Fixtures Shop Owners Common Toilets in Market / Public Toilet for Floating
No. Mall Building Population
Male Female Male Female Male Female
(1) (2) (3) (4) (5) (6) (7) (8)
i) Water 1 per 8 persons or part 1 for up to 15 1 for up to 12 1 per 50 1 per 50
Closets thereof 2 for 16-35 2 for 13-25 (Minimum (Minimum 2)
3 for 36-65 3 for 26-40 2)
4 for 66-100 4 for 41-57
5 for 58-77
6 for 78-100
iii) Urinals ---- ---- Nil up to 6 ---- 1 per 50 ----
1 for 7-20
2 for 21-45
3 for 46-70
4 for 71-100
Table No.12-P Sanitation Requirements – Airports and Railway Stations
Sr. Fixtures Junction Stations, Terminal Railway and Domestic and International
No. Intermediate Stations and Bus Stations Airports
Bus Stations
Male Female Male Female Male Female
(1) (2) (3) (4) (5) (6) (7) (8)
i) Water- 3 for up to 4 for up to 4 for up to 5 for up to Minimum - 2 Minimum - 2
closet 1000 Add 1 1000 Add 1 1000 Add 1 1000 Add 1 for 200 - 2 For 200 - 2
per per per per For 400 - 9 For 400 - 9
additional additional additional additional For 600 - 12 For 600 - 12
1000 or part 1000 or part 1000 or 1000 or For 800 - 16 For 800 - 16
thereof thereof part thereof part thereof For 1000 - 18 For 1000 - 18
ii) Urinals 4 for up to ---- 6 for up to ---- 1 per 40 or ----
1000. Add 1 1000. Add part thereof
per 1 per
additional additional
1000 1000
iii) Toilet 1 per 4000 1 per 4000 1 per 4000 1 per 4000 1 per 4000 1 per 4000
for (Minimum 1) (Minimum 1)
Disabled
-*-*-*-*-*-