UDCPR 2020 / Chapter 12, Structural safety, water supply, drainage and sanitary requirements, outdoor display and other services
Table 12-N Sanitation Requirements – Hostels
UDCPR 2020 as amended to 30.01.2025
Table No.12-N Sanitation Requirements – Hostels
Sr. Fixtures Resident Non-Resident Visitor / Common Rooms
No. Male Female Male Female Male Female
(1) (2) (3) (4) (5) (6) (7) (8)
i) Water 1 per 8 or 1 per 6 or 1 for up to 15 1 for up to 12 1 per 100 up 1 per 200 up
Closet part part 2 for 16-35 2 for 13-25 to 400 to 200
thereof thereof Over 400 add Over 200
3 for 36-65 3 for 26-40
at 1 per 250 add at 1 per
4 for 66-100 4 for 41-57
5 for 58-77
6 for 78-100
iii) Urinals 1 per 25 ---- Nil up to 6 ---- 1 per 50 or ----
or part 1 for 7-20 part thereof
thereof
2 for 21-45
3 for 46-70
4 for 71-100
To see how Table 12-N and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.
The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.