UDCPR 2020 / Chapter 12, Structural safety, water supply, drainage and sanitary requirements, outdoor display and other services

Table 12-O Sanitation Requirements – Mercantile Buildings, Commercial Complexes, Shopping

UDCPR 2020 as amended to 30.01.2025

Table No.12-O Sanitation Requirements – Mercantile Buildings, Commercial Complexes, Shopping
                                Malls, Fruit & Vegetable Markets
Sr. Fixtures         Shop Owners          Common Toilets in Market /     Public Toilet for Floating
No.                                                Mall Building                 Population
                  Male        Female          Male            Female        Male          Female
(1)     (2)         (3)          (4)           (5)               (6)         (7)            (8)
 i)    Water        1 per 8 persons or part 1 for up to 15               1 for up to 12      1 per 50 1 per 50
       Closets      thereof                 2 for 16-35                  2 for 13-25         (Minimum (Minimum 2)
                                            3 for 36-65                  3 for 26-40         2)
                                            4 for 66-100                 4 for 41-57
                                                                         5 for 58-77
                                                                         6 for 78-100
iii)   Urinals          ----              ----       Nil up to 6               ----          1 per 50               ----
                                                     1 for 7-20
                                                     2 for 21-45
                                                     3 for 46-70
                                                     4 for 71-100

                Table No.12-P Sanitation Requirements – Airports and Railway Stations
Sr.    Fixtures       Junction Stations,       Terminal Railway and      Domestic and International
No.               Intermediate Stations and        Bus Stations                    Airports
                         Bus Stations
                      Male         Female       Male         Female         Male           Female
(1)       (2)          (3)           (4)         (5)           (6)           (7)             (8)
i)     Water-     3 for up to    4 for up to    4 for up to    5 for up to     Minimum - 2     Minimum - 2
       closet     1000 Add 1     1000 Add 1     1000 Add 1     1000 Add 1      for 200 - 2     For 200 - 2
                  per            per            per            per             For 400 - 9     For 400 - 9
                  additional     additional     additional     additional      For 600 - 12    For 600 - 12
                  1000 or part   1000 or part   1000      or   1000       or   For 800 - 16    For 800 - 16
                  thereof        thereof        part thereof   part thereof    For 1000 - 18   For 1000 - 18
ii)    Urinals    4 for up to    ----           6 for up to    ----            1 per 40 or     ----
                  1000. Add 1                   1000. Add                      part thereof
                  per                           1        per
                  additional                    additional
                  1000                          1000
iii)   Toilet     1 per 4000     1 per 4000     1 per 4000     1 per 4000      1 per 4000 1 per 4000
       for                                                                     (Minimum 1) (Minimum 1)
       Disabled

                                              -*-*-*-*-*-

To see how Table 12-O and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.

The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.