UDCPR 2020 / Chapter 6, General building requirements - setback, marginal distance, height and permissible FSI

Table 6-A Residential Buildings / Residential Buildings with mixed-use (6.1.1)

UDCPR 2020 as amended to 30.01.2025

Table No.6-A
      Sr.       Road width in            Basic        For all Municipal Corporations and                  For remaining authorities / areas
                                                      (2)
      No.          meter                  FSI             CIDCO as Planning Authority by
                                                               Virtue of NTDA
                                                     FSI on         Maximum             Maximum             FSI on     Maximum Maxi-
                                                    payment         permissible         building          payment of   permissible mum
                                                       of               TDR            potential on        premium         TDR     building
                                                    premium           loading              plot                          loading  poten-tial
                                                                                                                                     on plot
       1                 2                  3            4                 5                    6             7             8          9
       1      Below 9.0 m.               1.50            --                --                  1.50           --            --       1.50
       2      9.0 m. and                 2.00          0.30             0.30                   2.60         0.30          0.10       2.40
              below 18.0 m.
       3      18.0 m. and                2.00          0.30             0.50                   2.80         0.30          0.20       2.50
              below 30.0 m.
       4      30.0 m. and                2.00          0.30             0.70                   3.00         0.30          0.20       2.50
              above
ii) Front Marginal Distances / Setback / Roadside Margin/s in Congested Area
        The minimum front setback from the existing or proposed road / roads shall be as per the
        following Table No.6-B.