UDCPR 2020 / Chapter 6, General building requirements - setback, marginal distance, height and permissible FSI
Table 6-A Residential Buildings / Residential Buildings with mixed-use (6.1.1)
UDCPR 2020 as amended to 30.01.2025
Table No.6-A
Sr. Road width in Basic For all Municipal Corporations and For remaining authorities / areas
(2)
No. meter FSI CIDCO as Planning Authority by
Virtue of NTDA
FSI on Maximum Maximum FSI on Maximum Maxi-
payment permissible building payment of permissible mum
of TDR potential on premium TDR building
premium loading plot loading poten-tial
on plot
1 2 3 4 5 6 7 8 9
1 Below 9.0 m. 1.50 -- -- 1.50 -- -- 1.50
2 9.0 m. and 2.00 0.30 0.30 2.60 0.30 0.10 2.40
below 18.0 m.
3 18.0 m. and 2.00 0.30 0.50 2.80 0.30 0.20 2.50
below 30.0 m.
4 30.0 m. and 2.00 0.30 0.70 3.00 0.30 0.20 2.50
above
ii) Front Marginal Distances / Setback / Roadside Margin/s in Congested Area
The minimum front setback from the existing or proposed road / roads shall be as per the
following Table No.6-B.