UDCPR 2020 / Chapter 6, General building requirements - setback, marginal distance, height and permissible FSI
Table 6-B Residential Buildings / Residential Buildings with mixed-use (6.1.1)
UDCPR 2020 as amended to 30.01.2025
Table No.6-B
Sr. Road width For Residential For Residential Buildings with
No. building mixeduse
(i) For streets / lane less than 2.25 m. from the 2.25 m. + 1.50 m. from the centre
4.5 m. width centre of the street / of the street / lane
lane
(ii) For streets 4.5 m. to less NIL 1.50 m.
than 6.0 m. in width
(iii) For streets 6.0 m. to less 1.00 m. 2.00 m.
than 12.0 m. in width
(iv) For streets 12.0 m. in width 2.00 m. 2.50 m.
and above
(1)
Inserted Vide AddendumNo.CR.236/18, dt.14th January, 2021
(2)
Inserted vide Notification u/s.37(1AA)(c) No.CR.236/18 (Part 6), dt.12th October, 2022
iii) Side and Rear Marginal Distances in Congested Area
The minimum side and rear marginal distances shall be as per the following Table No.6-C.
To see how Table 6-B and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.
UDCPR 2020, Table 6-B, as amended to 30.01.2025. https://citiwise.in/udcpr/table-6-b
Source
These words are UDCPR 2020 as the Directorate of Town Planning, Government of Maharashtra, publishes it in its consolidated text, as amended to 30.01.2025 with earlier provisions and corrections. Table 6-B is printed on pages 106 to 107 of that text. Read the official text (PDF).
The amendments noted beside these words in the official text:
- Inserted vide Addendum No.CR.236/18, dt. 14th January, 2021.
- Inserted vide Notification u/s.37(1AA)(c) No.CR.236/18 (Part 6), dt. 12th October, 2022.
The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.