UDCPR 2020 / Chapter 9, Requirements of part of building
9.28.5 Occupant Load
UDCPR 2020 as amended to 30.01.2025
For determining the exits required, the number of persons within any floor area or the occupant load shall be based on the actual number of occupants, but in no case less than that specified in Table No.9-E below :-
Table No.9-E Sr. Occupant Load Floor Area Group of Occupancy No. in sq.m. per person
(1) (2) (3)
1 Residential 12.5
2 Educational 4.0
3 Institutional 15 (See Note i)
4 Assembly
a) With fixed or loose seat and dance 0.6 (See Note ii)
floors
b) Without seating facilities including 1.5 (See Note ii) dining rooms
5) Mercantile
a) Street floor & Sales basement 3
b) Upper sale floors 6
6) Business and industrial 10
7) Storage 30
8) Hazardous 10
(1) Inserted Vide Corrigendum / Addendum No.CR.79/2021, dt.02nd December, 2021
Note :
i) Occupant load in dormitory portions of homes for the aged, orphanages, insane, asylums etc. where sleeping accommodation provided, shall be calculated at not less than 7.5 Sq.m. gross floor area per person.
ii) The gross floor area shall include, in addition to the main assembly rooms or space, any occupied connecting room or space in the same storey or in the storeys above or below where entrance is common to such rooms and spaces and they are available for use by the occupants of the assembly place. No deductions shall be made in the area for corridors, closets or other subdivisions, that area shall include all space serving the particular assembly occupancy.
Tables under this regulation: Table 9-E.
To see how 9.28.5 and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.
The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.