UDCPR 2020 / Chapter 14, Special schemes
Table 14-Q For Nagpur Municipal Corporation and Nagpur Metropolitan Region (14.2.3)
UDCPR 2020 as amended to 30.01.2025
Table No.14-Q
Sr. Building Height Side and Rear Remark
No. Margins
a 15.0 m. and H/2-4 Minimum 3.0 m. for Residential
below minimum 4.5 m. for Commercial and
Minimum 6.0 m. for Special Buildings.
b Above 15.0 m. Minimum 4.5 m. for Residential and
and upto 24.0 H/5 Commercial Building and 6.0 m. for
m. Special Building.
c Above 24.0 m. Minimum 6.0 m.
Note - 1. Maximum Side / Rear / Front Margin shall be 12.0 m. However if Developer /
Owners provides more than 12.0 m. side and rear margins it may be allowed.
Note - 2. The Municipal Commissioner may relax the side & rear marginal distances as per
Regulation No.2.4 of UDCPR subject to following provisions.
A) If clear minimum marginal distance is proposed from one side as per these
Regulation then other side marginal distance may be relaxed up to 50%.
B) Front margin relaxation to allow additional FSI may be granted subject to
condition that the Minimum road width shall be 12.0 m. and above.
Note - 3. In case semi-detached construction as per these regulations, common wall
constructed is allowed and marginal distance shall be provided for other side as per
these regulations.
(v)(a) No projections shall be allowed in one side marginal spaces as mentioned in
Note No.2(A) above so that this marginal spaces remain free from all encumbrances for
the movement of fire tenders. However open balconies may be allowed in the marginal
spaces where concession as mentioned in Note No.2(A) above is allowed, after leaving
minimum 3.0 m. distance from the plot boundaries, subject to Fire NOC.
In case if ramp is necessary from accessibility, such ramp may be allowed after living
6.0 m. clear margin. However such Ramp may be allowed in side margin where
relaxation is to granted as per provision mentioned in Note No.2(A) above subject to
NOC of the Fire Department.
(v)b) For calculation of marginal distances, the height of the parking floors (Maximum two
floors above the Ground Level) shall not be taken in account, However height of such
parking floors will be counted towards the total height of the building for deciding the
building as high rise building and for civil Aviation purpose.
(v)(c) Car lift / mechanical parking shall be permissible, as per these regulations as amended
from time to time.
vi) Parking :
Parking in the NMRC shall be provided as per the table given below :-
To see how Table 14-Q and the rest of UDCPR apply to a particular plot, with the clause behind every figure, open Citiwise.
The text of the Unified Development Control and Promotion Regulations for Maharashtra State, as amended to 30.01.2025. The notification of the Urban Development Department, Government of Maharashtra, is the authoritative text.